Eagleby Outsource China

Hierarchical resource tracking

AI Energy

Compare input against output across complex monitoring networks.

A tracking and reporting system for power, water, gas or any continuous utility. It organises meters into a parent-child tree, compares total intake with downstream consumption and surfaces losses, double-counting and silent meters automatically.

reconciliation in the reference site
0.3%
power, water, gas, steam
Any utility
to deploy
Ready

A moment with AI Energy

Main grid intake 12,480 kWh. Building Wing A 4,210, Production Line 2 3,890. Meter #14 has been silent for two hours, so the system fills the gap from its history and still reconciles the site to within 0.3%. The one branch that does not add up is a leak.

The problem it removes

Utility data arrives as hundreds of meter readings with no structure.

Nobody can say which wing, which line or which tenant consumed what, a dead meter leaves a hole in every total, and losses hide in the difference between what came in and what was used.

Hierarchical site mapping01 / 06

Capability 1

Hierarchical site mapping

Infrastructure as a dynamic tree: supply at the top, branching into wings, zones, lines or machines, so related streams are grouped and compared.

Predictive gap-filling02 / 06

Capability 2

Predictive gap-filling

When a sensor or meter goes offline, missing readings are estimated from historical patterns so reports and totals stay complete.

Reconciliation audits03 / 06

Capability 3

Reconciliation audits

Continuous comparison of inputs with outputs; imbalances flag leaks, double-counting or transmission losses.

Centralised analytics04 / 06

Capability 4

Centralised analytics

A web console for point-and-click analysis, custom time ranges, node health review and an archive of browser-ready reports.

Tenant and line allocation05 / 06

Capability 5

Tenant and line allocation

Utilities tracked and billed across multi-tenant spaces or output lines, supporting fair cost allocation and sustainability reporting.

Silence alerts06 / 06

Capability 6

Silence alerts

Teams are alerted when data stops arriving from any node, before the gap becomes a month of estimates.

How it works

Sense. Understand. Decide. Act.

  1. 01SenseCameras, radar, microphones, environmental and access sensors — chosen for the space, not the brochure.
  2. 02UnderstandVision and speech models run on an edge gateway in the room, so nothing waits for the cloud and nothing leaves it without consent.
  3. 03DecideScene rules and safety policies turn detections into decisions: escalate, notify, actuate, or stay quiet.
  4. 04ActLights, locks, motors, doors, screens, speakers and people — through open protocols and one operations console.

Operations

One console. Every event, with its evidence.

Live status, detections with the clip or image that triggered them, who was notified and what happened next. Per room, per car, per gate, per site.

AI Energy console
Specification · NT-04
InputsPower, water, gas and other continuous meters; environmental sensor networks
ModelParent-child tree of sites, zones, lines and equipment
AnalyticsGap-filling, reconciliation, benchmarking across matching periods
ConsoleWeb; custom ranges, node health, report archive
WorkflowMap the site → aggregate streams → smooth the gaps → audit the balance

Integrations

  • Modbus meters
  • MQTT sensors
  • BMS
  • Utility APIs
  • Excel
  • PDF
  • Eagle ColdLine

Deployments

Where it goes to work.

01

Facilities and campuses

Utilities tracked and billed across tenants and wings; sustainability compliance from the same data.

02

Industrial plants

Intake linked to output lines and machinery to find units that use disproportionate resources at peak times.

03

Distribution loops

Long-distance flow monitored from intake to destination; leaks isolated where downstream totals stop matching.

Questions

What clients ask first.

What happens when a meter dies?

The system estimates its readings from historical patterns, marks them as estimated, alerts the team and keeps the site totals reconciled.

Can we benchmark sites against each other?

Yes. Dispersed sites sit under one tree and are compared over matching periods.

Which utilities are supported?

Any continuous stream: electricity, water, gas, steam, compressed air, and environmental sensors.

NT-04 · AI Energy

Tell us about your site. We come back with a design and a written quote.

A floor plan, deck plan, yard layout or garden drawing is the best start. Hardware is sourced from factories Outsource China inspects, and delivered on one contract.

Goes straight to the Eagle team. We reply within one business day with the questions we need answered to design it.